10 Structure of the drive axis
10.3 Drive concept
302
Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Control types
All Lenze inverters are provided with the linear V/f control (VFC) which, however, requires an over-
dimensioning of the inverter with regard to the motor. Moreover, the motor may only be utilised to
approx. 75 % of the rated torque.
Servo Drives 9400 are provided with the special Voltage Vector Control (VVC) motor management
which is suitable for vertical conveyors with encoderless drive systems. This procedure ensures a
motor excitement coordinated to each operating status. For this purpose, the rated output current
of the inverter has to be at least 120 % of the rated motor current.
Suitable control types
VFCplus with VVC
V/f control with linear V/f characteristic
VVC: Voltage Vector Control
VVC is activated via parameters
Suitable for motor power 55 kW
Contained in Servo Drives 9400
•VFCplus linear
V/f control with linear V/f characteristic
Suitable for motor power 7.5 kW (recommended limit value)
Contained in all Lenze inverters
Tip!
Lenze Servo Drives 9400 with VVC are recommendable for vertical conveyors with en-
coderless drive system 55 kW.
Always execute drive systems >55 kW with feedback.
Unsuitable control types
•VFCplus square-law
V/f control with square-law V/f characteristic
•VFCplus eco
Energetically optimised V/F control
•SLVC
Sensorless vector control