Lenze DSD User Manual Page 273

  • Download
  • Add to my manuals
  • Print
  • Page
    / 496
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 272
Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23 273
8 Motion design
8.3 Predefined motion profile according to operating mode
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8.3.4 Intermittent load S6, S7
Operation composed of a sequence of identical cycles each of which including an operating time
with constant load and an idle time. There is no idle time.
[8-12] Motion profile for operating mode S6
ED
t t
t
acc
t
dec
Description
t Cycle time, corresponds to the duration of the load phase.
t
acc
Acceleration time required by the drive until the constant load condition is reached.
t
dec
Deceleration time required by the drive until standstill.
OT Relative operating time
• Percentage ratio of duration of load phase to duration of no-load phase.
Page view 272
1 2 ... 268 269 270 271 272 273 274 275 276 277 278 ... 495 496

Comments to this Manuals

No comments