7Applications
7.21 Dimension the multi-axis system
196
Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Coordinated multi-axis system
In a coordinated multi-axis system, the motion sequences are in a permanently time-defined rela-
tionship (e.g. applications with cams or clock-related systems).
In the DSD, you can optimally dimension a multi-axis system with coordinated drive axes relat-
ing to energy.
Lenze BlueGreen Solutions serves to calculate amortisation times quickly. The cost-cutting po-
tentials are documented in an Energy Performance Certificate.
Energy efficiency
( 378)
[7-194] Power characteristic of two coordinated drive axes
Uncoordinated multi-axis system
Uncoordinated motion sequences are not associated with regard to time. Even if only single drive
axes of the multi-axis system are uncoordinated, the DSD calculates with the most unfavourable
power characteristic:
The peak powers of all single axes occur at the same time.
The supply components of the network must provide the sum of peak powers in generator
mode and in motor mode of all drive axes.
[7-195] Power characteristic for two uncoordinated drive axes
Power characteristic drive axis 1
Power characteristic drive axis 2
Total power
Power characteristic drive axis 1
Power characteristic drive axis 2
The determination of the total power is not possible because there is no relationship between the power character-
istics.