Lenze DSD User Manual Page 280

  • Download
  • Add to my manuals
  • Print
  • Page
    / 496
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 279
9 Mains and environment
9.2 Ambient conditions
280
Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
9.2.3 Site altitude
The components can be operated up to a site altitude of 1000 m amsl without power reduction.
From 1000 ... 4000 m amsl there is a power reduction.
For inverters the derating factor is stored in the DSD device-specifically.
The site altitude for geared motors is considered as a function of the temperature:
For motors without a gearbox, the following applies:
ϑ
opr
k
h
1000 m 2000 m 3000 m 4000 m
20 °C 1.15 1.04 0.92 0.81
30 °C 1 0.9 0.8 0.70
40 °C 0.8 0.72 0.64 0.56
50 °C 0.6 0.54 0.48 0.42
60 °C 0.4 0.36 0.32 0.28
h k
h
0 ... 1000 m 1
2000 m 0.95
3000 m 0.9
4000 m 0.85
Page view 279