Parameter | Name:
C02601 | Ref. for Accel. time of brake
Data type: UNSIGNED_32
Index: 21974
d
= 55D6
h
From software version V3.0
๏ดBasic function "Brake control
"
Selection list (Lenze setting printed in bold)
0 Motor reference value
1 Current starting value
๏พ Read access ๏พ Write access ๏จ CINH ๏จ PLC STOP ๏จ No transfer Scaling factor: 1
Parameter | Name:
C02602 | Source for feedf. control brake
Data type: UNSIGNED_32
Index: 21973
d
= 55D5
h
From software version V3.0
๏ดBasic function "Brake control
"
Selection list (Lenze setting printed in bold)
0Torque
1 Speed
๏พ Read access ๏พ Write access ๏จ CINH ๏จ PLC STOP ๏จ No transfer Scaling factor: 1
Parameter | Name:
C02603 | Threshold 1 for opening brake
Data type: INTEGER_32
Index: 21972
d
= 55D4
h
From software version V3.0
๏ดBasic function "Brake control
"
Setting range (min. value | unit | max. value) Lenze setting
-50000 rpm 50000 0rpm
๏พ Read access ๏พ Write access ๏จ CINH ๏จ PLC STOP ๏จ No transfer Scaling factor: 1
Parameter | Name:
C02604 | Threshold 2 for opening brake
Data type: INTEGER_32
Index: 21971
d
= 55D3
h
From software version V3.0
๏ดBasic function "Brake control
"
Setting range (min. value | unit | max. value) Lenze setting
-50000 rpm 50000 0rpm
๏พ Read access ๏พ Write access ๏จ CINH ๏จ PLC STOP ๏จ No transfer Scaling factor: 1