Lenze 9400 User Manual Page 457

  • Download
  • Add to my manuals
  • Print
  • Page
    / 954
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 456
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 457
11 Basic drive functions
11.6 Homing
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Mode 1015: DS402 homing method 15
Reserved: no homing is executed.
Mode 1016: DS402 homing method 16
Reserved: no homing is executed.
Mode 1017: DS402 homing method 17
Procedure:
1. Movement in negative direction with profile data set 1.
2. Reversing to negative travel range limit switch and change to profile data set 2.
3. The following negative edge of the travel range limit switch sets the reference.
4. Absolute positioning to target position (C02643
) with profile data set 2 (if C02641 ="0").
Mode 1018: DS402 homing method 18
Procedure:
1. Movement in positive direction with profile data set 1.
2. Reversing to positive travel range limit switch and change to profile data set 2.
3. The following negative edge of the travel range limit switch sets the reference.
4. Absolute positioning to target position (C02643
) with profile data set 2 (if C02641 ="0").
Negative travel range limit switch
1
0
Positive travel range limit switch
1
0
Page view 456
1 2 ... 452 453 454 455 456 457 458 459 460 461 462 ... 953 954

Comments to this Manuals

No comments