13 Diagnostics & fault analysis
13.7 Error messages of the operating system
614
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
13.7.2 Reset error message
An error message with the response "Fault", "Quick stop by trouble", or "Warning locked" must be
reset (acknowledged) explicitly after the cause of error has been eliminated.
To reset (acknowledge) a pending error message, execute the device command
C00002
= "43: Reset error".
Tip!
When an online connection to the controller has been established, use the Diagnostics tab
of »Engineer« and click Reset error to reset a pending error message.