Lenze 9400 User Manual Page 440

  • Download
  • Add to my manuals
  • Print
  • Page
    / 954
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 439
11 Basic drive functions
11.6 Homing
440
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
11.6.4 Overview of DS402 homing modes
This function extension is available from software version V3.0!
In addition to the homing modes described in the previous subchapter "Overview of the Lenze
homing modes", from software version V3.0 also the homing modes described in the following can
be selected for a homing in C02640
, according to the DS402 device profile.
The switches/sensors are evaluated via the following internal interfaces:
DS402
homing method
Evaluated signals/sensors
Touch probe sensor/
encoder zero pulse
Travel range limit switch Reference switch at
HM_bHomingMark
Negative limit switch Positive limit switch
01 
02 
03 
04 
05 
06 
07 
08 
09 
10 
11 
12 
13 
14 
15 Reserved: no homing is executed.
16 Reserved: no homing is executed.
17
18
19
20
21
22
23 
24 
25 
26 
27 
28 
29 
30 
31 Reserved: no homing is executed.
32 Reserved: no homing is executed.
33
34
35 Direct reference setting.
Page view 439
1 2 ... 435 436 437 438 439 440 441 442 443 444 445 ... 953 954

Comments to this Manuals

No comments