11 Parameter reference
11.2 Parameter list | C00242
370
Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00242
C00243
C00244
C00245
Parameter | Name:
C00242 | L_PCTRL_1: Operating mode
Data type: UNSIGNED_8
Index: 24333
d
= 5F0D
h
The L_PCTRL_1 FB: Selection of the operating mode
Depending on the selection, the blue switches in the displayed signal flow are set accordingly in the Engineer on
the Application parameter tab in the Overview Signal flow Process controller dialog level.
Selection list (Lenze setting printed in bold) Info
0Off The input setpoint nNSet_a is output without any
changes at the output nOut_a.
1nNSet + nNSet_PID nNSet_a and nAct_a are used as PID input values. The
arriving nNSet_a is additively linked to the value output
by the PID element.
2nSet_PID nSet_a and nAct_a are used as PID input values. The
input nNSet_a is not considered.
3nNSet_PID nNSet_a and nAct_a are used as PID input values. The
input nSet_a is not considered.
4 nNSet + nSet_PID From version 04.00.00
nSet_a and nAct_a are used as PID input values. The
arriving nNSet_a setpoint is additively linked to the value
output by the PID element.
5 nNSet || nSet_PID From version 04.00.00
nSet_a and nAct_a are used as PID input values. The
setpoint nNSet_a is output at the output nOut_a . The
PID output value is output at the output nPIDOut_a.
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00243 | L_PCTRL_1: Acceleration time influence
Data type: UNSIGNED_32
Index: 24332
d
= 5F0C
h
The L_PCTRL_1 FB: Acceleration time for showing the PID output value
Setting range (min. value | unit | max. value) Lenze setting
0.0 s 999.9 5.0 s
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1000
Parameter | Name:
C00244 | L_PCTRL_1: Deceleration time influence
Data type: UNSIGNED_32
Index: 24331
d
= 5F0B
h
The L_PCTRL_1 FB: Deceleration time for masking out the PID output value
Setting range (min. value | unit | max. value) Lenze setting
0.0 s 999.9 5.0 s
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1000
Parameter | Name:
C00245 | L_PCTRL_1: PID output value
Data type: INTEGER_16
Index: 24330
d
= 5F0A
h
The L_PCTRL_1 FB: Display of the output value of the PID process controller
Display range (min. value | unit | max. value)
-199.9 % 199.9
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100