9 Diagnostics & error management
9.8 Error messages of the operating system
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
9.8.1.4 Example for bit coding of the error number
C00161/1 displays the internal error number "75169803".
This decimal value corresponds to the following bit sequence:
Thus, error number "75169803" means:
An overcurrent has been detected in the "Motor management/encoder" subject area. A pulse in-
hibit is set as error response. The error message must be acknowledged after the error has been
eliminated.
Assignment Information Meaning in the example
Reserved -
Error type 1: Fault (pulse inhibit)
Error subject area 123: Motor management / encoder
Error ID 13: "LU: DC bus undervoltage
"