11 Parameter reference
11.2 Parameter list | C00028
340
Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00028
C00029
C00033
Parameter | Name:
C00028 | AINx: Input voltage
Data type: INTEGER_16
Index: 24547
d
= 5FE3
h
Display of the input voltage at the analog inputs
Analog terminals
Display range (min. value | unit | max. value)
-10.0 V 10.0
Subcodes Info
C00028/1 AIN1: Input voltage
C00028/2 AIN2: Input voltage
• From version 04.00.00
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00029 | AINx: Input current
Data type: INTEGER_16
Index: 24546
d
= 5FE2
h
Display of the Input current at the analog input
• When the analog input is configured for current measurement (C00034/1
=1 or 2).
•When C00034/1
is set = 2 (4 ... 20 mA), 0 ... 16 mA is displayed.
Analog terminals
Display range (min. value | unit | max. value)
0.0 mA 20.0
Subcodes Info
C00029/1 AIN1: Input current
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00033 | AINx: Output value
Data type: INTEGER_16
Index: 24542
d
= 5FDE
h
Display of the output value in percent of the analog input amplifier
• 100 % ≡ 16384 ≡ +10 V / +20 mA
Analog terminals
Display range (min. value | unit | max. value)
-199.9 % 199.9
Subcodes Info
C00033/1 AIN1: Output value
C00033/2 AIN2: Output value
• From version 04.00.00
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100