Lenze E82ZAFIC010 User Manual Page 58

  • Download
  • Add to my manuals
  • Print
  • Page
    / 71
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 57
Codetabelle
Communication−relevant Lenze codes
10
l
58
EDS82ZAFIC EN 2.0
10.1 Communication−relevant Lenze codes
C1510:
Configuring process input data
Code
C1510
Name
Configuring process input data
Index
0x5A19 (23065)
Subcode Lenze Values Access Data type
1 PIW1 18
see table below rw FIX32
2 PIW2 3
3 PIW3 4
4 PIW 4 5
þ Parameter set transfer
The assignment of the bit status information or actual values of the controller to the max.
4 process input data words (PIW) of the master can be configured freely.
) Note!
For reasons of compatibility, subcodes 5 and 6 can also be read and written
with modules from software version V3.0. However, this has no effect.
Selection Scaling
1 FIF status word 1 (FIF−STAT1) 16 bits
2 FIF status word 2 (FIF−STAT2) 16 bits
3 Output frequency with slip (MCTRL1−NOUT+SLIP) ±24000 º ±480 Hz
4 Output frequency without slip (MCTRL1−NOUT) ±24000 º ±480 Hz
5 Apparent motor current (MCTRL1−IMOT) 2
14
º 100 % rated device current
6 Actual process controller value (PCTRL1−ACT) ±24000 º ±480 Hz
7 Process controller setpoint (PCTRL1−SET) ±24000 º ±480 Hz
8 Process controller output (PCTRL1−OUT) ±24000 º ±480 Hz
9 Device utilisation (MCTRL1−MOUT) ±2
14
º ±100 % rated motor torque
10 DC−bus voltage (MCTRL1−DCVOLT) 16383 º 565 VDC at 400 V mains
16383 º 325 VDC at 230 V mains
11 Ramp function generator input (NSET1−RFG1−IN) ±24000 º ±480 Hz
12 Ramp function generator output (NSET1−NOUT) ±24000 º ±480 Hz
13 FIF−OUT.W1 16 bits or 0 ... 65535
14 FIF−OUT.W2 16 bits or 0 ... 65535
15 FIF−OUT.W3 0 ... 65535
16 FIF−OUT.W4 0 ... 65535
17 DRIVECOM control word (DRIVECOM−CTRL) 16 bits
18 DRIVECOM status word (DRIVECOM−STAT) 16 bits