C0002:
Parameter set management
(extract)
Code
C0002
Name
Parameter set management
Index
0x5FFD (24573)
Subcode Lenze Values Access Data type
−0
0 Ready rw FIX32
1 Lenze setting ð PAR1 rw FIX32
2 Lenze setting ð PAR2 rw FIX32
3 Lenze setting ð PAR3 rw FIX32
4 Lenze setting ð PAR4 rw FIX32
31 Lenze setting ð FPAR1 rw FIX32
61 Lenze setting ð PAR1 + FPAR1 rw FIX32
62 Lenze setting ð PAR2 + FPAR1 rw FIX32
63 Lenze setting ð PAR3 + FPAR1 rw FIX32
64 Lenze setting ð PAR4 + FPAR1 rw FIX32
þ Parameter set transfer
In the controller, up to 4 parameter sets (PAR1 ... PAR4) can be saved. In the
function/communication module, 1 parameter set (FPAR1) can be saved.
By means of parameter setting, the parameter set or sets can be defined in which the
delivery status is to be established.