Lenze HMI for visualisation / with control technology User Manual Page 30

  • Download
  • Add to my manuals
  • Print
  • Page
    / 96
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 29
Electrical installation
Wiring
EL 1xx CAN/PLC/MPI
6
30
LDCDS−EL100 EN 9.0
6.3 Wiring
6.3.1 EL 1xx CAN/PLC/MPI
Mains connection
Note!
ƒ Observe the max. permissible input voltage.
Professionally fuse the device on the input side against voltage fluctuations
and voltage peaks.
ƒ The HMI boots up as soon as the supply voltage is applied.
After the operating system has been shut down, the HMI switches off
automatically. For restarting, the supply voltage has to be disconnected for a
short time.
EL100−005
Description Connection type Cable type
0V U
DC 24 V connection
3−pole Phoenix Combicon
socket
Cable (conductor
cross−section max. 2.5 mm
2
)
with Phoenix Combicon plug,
MSTB 2.5 / 3−STF−5.08
IPC001
PE connection Threaded bolt M4
Separate earthing conductor
(min. 2.5 mm
2
) with ring
cable lug
IPC001