Changing lubricant
Stop!
¯ Gearbox should be warm.
¯ Secure drive system and machine from inadvertent movement and
mains connection.
The type of lubricant indicated on the nameplate by the following manufacturers is
approved.
Shell Klüber Fuchs
1. Place receptacle under oil drain plug.
2. Remove breating / oil filler plug.
3. Completely drain lubricant by removing the oil drain plug.
4. Reinsert drain plug (if necessary, replace seal).
5. Fill in lubricant through filler hole (quantities see nameplate).
6. Screw in breathing / oil filler plug.
7. Dispose of waste oil according to the applicable regulations.