6 Electrical installation
Wiring to a host
EDK82ZAFCC-010 DE/EN/FR 5.0
44
H2 VerdrahtLeitrechner-leitungsspez
Wiring to a host
E82ZAFC013
Fig. 1 Basic structure
Specification of the transmission cable
We recommend the use of CAN cables in accordance with ISO 11898-2:
CAN cable in accordance with ISO 11898-2
Cable type Paired with shielding
Impedance
120
( 95 ... 140
)
Cable resistance / cross-section
Cable length
300 m
70 m
/m / 0.25 … 0.34 mm
2
(AWG22)
Cable length 301 … 1000 m
40 m
/m / 0.5 mm
2
(AWG20)
Signal propagation delay
5 ns/m