9400 Technology applications | Positioning sequence control
Parameter setting & configuration
Brake control
60 L EDS94TA10060xxxx EN 1.2 - 03/2010
Control/setpoint inputs of the function Signal configuration
Lenze setting Control/setpoint input (Multiplexer parameters)
FALSE Open brake (release) C03165/1
FALSE Activate starting torque 2 C03165/2
FALSE Keep open brake at standstill C03165/3
FALSE Brake status signal C03165/4
FALSE Activate brake test C03165/5
FALSE Grind brake C03165/6
0 % Additional torque C03166