Lenze E94AxHE Technology Application Positioning sequenc User Manual Page 21

  • Download
  • Add to my manuals
  • Print
  • Page
    / 78
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 20
EDS94TA10060xxxx EN 1.2 - 03/2010 L 21
9400 Technology applications | Positioning sequence control
Short setup
Step 3: Parameterising the program flow
4.6.3 Program step 3: Positioning action 1
Click Profile settings to open the following dialog box:
1. Select Profile no. 1.
2. Select "Relative" as positioning mode.
3. Select the profile parameters as described above.
4. Click Back to close the dialog box again.
Action Comment Parameter Setting
When input 8 of sequence control is set to "1", lower
table relatively by 20 mm.
In the Lenze setting, sequence control input 8 is
connected to digital input DI8.
Selection Action Number: 1
Start with: Input 8
Profile no.: 1
Jump destination: 0