EDS94TA10060xxxx EN 1.2 - 03/2010 L 25
9400 Technology applications | Positioning sequence control
Short setup
Step 4: Parameterising the multiplexer for the digital outputs
4.7 Step 4: Parameterising the multiplexer for the digital outputs
1. Go to the All parameters tab.
2. Set the following multiplexer parameters:
Parameter Setting
C03100/2 X digital output 2 of Homing completed
C03100/3 X digital output 3 of Sequence control output 1