EDKVF93−03.MU|Ä.MU|äInformation for the operator of the machine9300 vector 45 ... 90 kWEVF9330−xV ... EVF9333−xVFrequency inverter Global Drive
Safety instructionsGeneral safety and application notes for Lenze controllers2 10EDKVF93−03 EN 3.0Application as directedControllers are compo
Safety instructionsGeneral safety and application notes for Lenze controllers2 11EDKVF93−03 EN 3.0Electrical connectionWhen working on live
Safety instructionsThermal motor monitoring2 12EDKVF93−03 EN 3.02.2 Thermal motor monitoring Note!From software version 8.1 onwards, the 930
Safety instructionsThermal motor monitoringForced ventilated or naturally ventilated motors2 13EDKVF93−03 EN 3.02.2.1 Forced ventilated or n
Safety instructionsThermal motor monitoringSelf−ventilated motors2 14EDKVF93−03 EN 3.02.2.2 Self−ventilated motorsDue to the construction, sel
Safety instructionsThermal motor monitoringSelf−ventilated motors2 15EDKVF93−03 EN 3.0Calculate release time and I2xt loadCalculate the rele
Safety instructionsResidual hazards2 16EDKVF93−03 EN 3.02.3 Residual hazardsProtection of personsƒ Before working on the controller, check tha
Safety instructionsResidual hazards2 17EDKVF93−03 EN 3.0Protection of the machine/systemƒ Drives can reach dangerous overspeeds (e. g. setti
Safety instructionsSafety instructions for the installation according to UL2 18EDKVF93−03 EN 3.0 2.4 Safety instructions for the installation
Safety instructionsSafety instructions for the installation according to UL2 19EDKVF93−03 EN 3.0 Original − French Warnings!ƒ Motor Overloa
9300vec160
Parameter settingParameter setting with the XT EMZ9371BC keypadGeneral data and operating conditions3 20EDKVF93−03 EN 3.03 Parameter setting3.
Parameter settingParameter setting with the XT EMZ9371BC keypadInstallation and commissioning3 21EDKVF93−03 EN 3.03.1.2 Installation and co
Parameter settingParameter setting with the XT EMZ9371BC keypadDisplay elements and function keys3 22EDKVF93−03 EN 3.0Displays Status display
Parameter settingParameter setting with the XT EMZ9371BC keypadChanging and saving parameters3 23EDKVF93−03 EN 3.0Function keys Note!Short
Parameter settingParameter setting with the XT EMZ9371BC keypadChanging and saving parameters3 24EDKVF93−03 EN 3.0ActionKeysequenceStep7. Acce
Parameter settingParameter setting with the XT EMZ9371BC keypadLoading a parameter set3 25EDKVF93−03 EN 3.0 3.1.5 Loading a parameter setTh
Parameter settingParameter setting with the XT EMZ9371BC keypadTransferring parameters to other standard devices3 26EDKVF93−03 EN 3.03.1.6 Tra
Parameter settingParameter setting with the XT EMZ9371BC keypadTransferring parameters to other standard devices3 27EDKVF93−03 EN 3.0Copyin
Parameter settingParameter setting with the XT EMZ9371BC keypadActivating password protection3 28EDKVF93−03 EN 3.03.1.7 Activating password pr
Parameter settingParameter setting with the XT EMZ9371BC keypadDiagnostics3 29EDKVF93−03 EN 3.03.1.8 DiagnosticsIn the "Diagnostic&quo
Key for overviewPosition Description Controller Fixing bracket for standard mounting EMC shield sheet with fixing screws for shielded control cabl
Parameter settingParameter setting with the XT EMZ9371BC keypadMenu structure3 30EDKVF93−03 EN 3.0 3.1.9 Menu structure For simple, user−frien
Parameter settingParameter setting with the XT EMZ9371BC keypadMenu structure3 31EDKVF93−03 EN 3.0DescriptionSubmenusMain menu DescriptionD
Troubleshooting and fault eliminationDisplay of operating data, diagnosticsDisplay of operating data4 32EDKVF93−03 EN 3.04 Troubleshooting and
Troubleshooting and fault eliminationDisplay of operating data, diagnosticsDiagnostics4 33EDKVF93−03 EN 3.0IMPORTANTPossible settingsCodeSel
Troubleshooting and fault eliminationTroubleshootingStatus display via controller LEDs4 34EDKVF93−03 EN 3.0 4.2 TroubleshootingDetecting break
Troubleshooting and fault eliminationTroubleshootingFault analysis with the history buffer4 35EDKVF93−03 EN 3.0 4.2.2 Fault analysis with th
Troubleshooting and fault eliminationDrive behaviour in the event of faultsFault analysis with the history buffer4 36EDKVF93−03 EN 3.0 4.3 Dri
Troubleshooting and fault eliminationFault eliminationDrive errors4 37EDKVF93−03 EN 3.04.4 Fault elimination 4.4.1 Drive errorsMalfunction C
Troubleshooting and fault eliminationFault eliminationController in clamp operation4 38EDKVF93−03 EN 3.04.4.2 Controller in clamp operationThe
Troubleshooting and fault eliminationFault eliminationBehaviour in case of overvoltage in the DC bus (OU message)4 39EDKVF93−03 EN 3.0 4.4.3
Contentsi 4EDKVF93−03 EN 3.01 About this documentation 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Troubleshooting and fault eliminationSystem error messagesGeneral error messages4 40EDKVF93−03 EN 3.0AdjustmentUDCt C0912³t < C0912t = C091
Troubleshooting and fault eliminationSystem error messagesGeneral error messages4 41EDKVF93−03 EN 3.0Fault messageDescription Cause RemedyNo
Troubleshooting and fault eliminationSystem error messagesGeneral error messages4 42EDKVF93−03 EN 3.0RemedyCauseDescriptionFault message Remed
Troubleshooting and fault eliminationSystem error messagesGeneral error messages4 43EDKVF93−03 EN 3.0RemedyCauseDescriptionFault message Rem
Troubleshooting and fault eliminationSystem error messagesGeneral error messages4 44EDKVF93−03 EN 3.0RemedyCauseDescriptionFault message Remed
Troubleshooting and fault eliminationSystem error messagesResetting system error messages4 45EDKVF93−03 EN 3.0RemedyCauseDescriptionFault me
& '© 11/2013FLenze Automation GmbHPostfach 10 13 52, D−31763 HamelnHans−Lenze−Str. 1, D−31855 AerzenGermanyService Lenze Service GmbHBreslaue
About this documentationDocument history1 5EDKVF93−03 EN 3.01 About this documentation Note!This documentation contains all the information
About this documentationValidity information1 6EDKVF93−03 EN 3.0 1.3 Validity information... 9300 vector frequency inverters as of nameplate d
About this documentationConventions used1 7EDKVF93−03 EN 3.0 1.4 Conventions usedThis documentation uses the following conventions to distin
About this documentationNotes used1 8EDKVF93−03 EN 3.0 1.5 Notes usedThe following pictographs and signal words are used in this documentation
Safety instructionsGeneral safety and application notes for Lenze controllers2 9EDKVF93−03 EN 3.02 Safety instructions2.1 General safety and
Comments to this Manuals