Lenze DDS Function library IOSystem User Manual Page 61

  • Download
  • Add to my manuals
  • Print
  • Page
    / 83
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 60
Function library LenzeIOSystem.lib
Function blocks
5.7 L_IOCounterDIModuleDataFromIO − Counter function
5−15
L
LenzeIOSystem.lib EN 1.7
5.7 L_IOCounterDIModuleDataFromIO − Counter function
Function block L_IOCounterDIModuleDataFromIO supplies the counter module’s counting
information.
The 32−bit value of the counter is supplied at output dwCounter.
L_IOCounterDIModuleDataFromIO
abyPDO_DataFromIO
Byte
0
DO
Byte
1
DO
Byte
2
DO
Byte
3
DO
Byte
4
DO
Byte
5
DO
dwCounter
Converter
byte to dw
bBit0
bBit15
ð Inputs (Variable type: VAR_INPUT)
Variable name Data type Information/possible settings
abyPDO_DataFromIO Byte array Interface with outputs of function blocks L_IOPDO15 or L_IOPDO610 for the
transfer of count values from the counter module.
Outputs ð (Variable type: VAR_OUTPUT)
Identifier Data type Value/meaning
dwCounter Double word Output count value
bBit0 − bBit15 Bool Output status of digital inputs 0...15