5.3 L_IOCompactModule − Coordinate data
Function library LenzeIOSystem.lib
Function blocks
5−10
L
LenzeIOSystem.lib EN 1.7
(Variable type: VAR_OUTPUT)Outputs ð
Identifier Value/meaningData type
bFail_DataToIO Bool Transmit command to I/O system
TRUE Transmit command to I/O system is not correct
bFail_DataFromIO Bool Receive command from I/O system
TRUE Receive command from I/O system is not correct
bFail_Module Bool Module error
TRUE · Module diagnostics active
· Emergency object indicates error
abyPDO1_DataFromIO Byte array I/O system transmit object
Transfer process data from I/O system to PLC
(digital inputs)