Electrical installation
TopLine C control terminals
Axis bus
6
240
EDS84ASC552 EN 9.1
Data transfer axis bus
Labelling Feature Rated value
X10/AH, AL Data transfer axis bus connection Acc. to CAN specification
Cable lengths: See CAN on board
Baud rate from version 12.00: 800 kbit/s, constant
up to version 2.xx: 500 kbps, constant
Terminating resistor 120 , switching via DIP switch
X10/AG GND, reference potential: Data transfer axis bus
Note!
Trouble-free operation of the axis bus is only possible if the following
requirements are met:
ƒ Use CAN cables in accordance with ISO 11898
ƒ Apply cable shields to both ends of the shield connections (functional earth)
In particular for longer cables, in the case of installation over several control
cabinets, o r in difficult EMC environments, further measures are required:
ƒ Establish equipotential bonding between the places of installation ( 167)
ƒ Use of a power choke at the mains connection