Lenze EVS9332xS User Manual Page 56

  • Download
  • Add to my manuals
  • Print
  • Page
    / 376
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 55
Installing of the standard device
Standard devices in the power range 0.37 ... 11 kW
Mounting in "cold plate" technique
4
4.1
4.1.4
4.1−5
EDSVS9332S EN 6.0−07/2013
a
c1
c
c
a
a
c
gg g
b1 b1 b1
dd d
bb b
LLL
210
e
<7C
3
9300std064
Fig. 4.1−3 Dimensions for mounting in "cold plate" technique 0.37 ... 11 kW
9300 Dimensions [mm]
Type a b b1 c c1 d e
1)
g
EVS9321−CS
EVS9322−CS
78 381 350 48 ˘ 367 168 6.5
EVS9323−CS
EVS9324−CS
97 381 350 67 ˘ 367 168 6.5
EVS9325−CS
EVS9326−CS
135 381 350 105 38 367 168 6.5
1)
For a fieldbus module plugged onto X1, consider mounting space for connecting cables
Apply heat conducting paste before screwing together the cooler and
cooling plate of the drive controller so that the heat transfer resistance is as
low as possible.
1. Fasten the fixing bracket with sheet metal screws 3.5 × 13 mm at the
top and bottom of the drive controller .
2. Clean the contact surface of cooler and cooling plate with spirit.
3. Apply a thin coat of heat conducting paste with a filling knife or brush.
– The heat conducting paste in the accessory kit is sufficient for an area
of approx. 1000 cm
2
.
4. Mount the drive controller on the cooler.
Dimensions