Lenze EVS9332xS User Manual Page 100

  • Download
  • Add to my manuals
  • Print
  • Page
    / 376
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 99
Wiring of the standard device
Standard devices in the power range 0.37 ... 11 kW
Mains connection, DC supply
5
5.4
5.4.3
5.4−5
EDSVS9332S EN 6.0−07/2013
L1 L2 L3
+UG -UG
PE
L1, L2, L3
+U , -U
GG
0.5...0.6 Nm
4.4...5.3 lb-in
2
0
1
9300std033
Fig. 5.4−3 Mains connection, DC supply for drive controllers 0.37 ... 11 kW
Mains cable
Shield sheet
Securely clamp mains cable with the lugs
Mains and DC bus connection
L1, L2, L3: Connection of mains cable
+U
G
, −U
G
: Connection of DC−bus components or connection of the controller
in the DC−bus system (see system manual)
Cable cross−sections up to 4 mm
2
: Use wire end ferrules for flexible cables
Cable cross−sections > 4 mm
2
: Use pin−end connectors
Mains connection, DC supply
Page view 99