HMI Designer
L
QQ
EDBHMI-DEEN DE/EN 4.0
QKRKS qê~åëãáí éêçàÉÅí íç íÜÉ âÉóé~Ç
The keypad must be connected to the PC. ( 31)
mêÉé~êÉ âÉóé~Ç bmjJePNM Ñçê íê~åëãáëëáçå
1. Keep the
F5
key at the keypad pressed.
2. Switch on the supply voltage for the keypad.
3. When “H310 service page” is displayed, release the
F5
key.
pí~êí Ç~í~ íê~åëãáëëáçå áå ejf aÉëáÖåÉê
Select Tools Transfer project... to open the Downloader dialog box.
1. In the section Communication port select the serial interface of your PC which is connected to
the download cable EPZ-H110.
2. In the section Baud rate select the baud rate (default: 115200 baud).
3. Tick Update operating unit program to transmit the program.
Ó If you want to update the system program of the keypad at the same time, mark Update
operating unit firmware in addition.
4. Click OK to start the data transmission.
The program is transmitted to the keypad.
After the transmission, the display of the keypad shows the first page (start page) of the project.