Lenze · 8400 BaseLine D · Reference manual · DMS 5.5 EN · 01/2014 · TD05 127
7 Drive application
7.1 Parameterisation dialog
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.1.1.1 Selection of the main speed setpoint
The main speed setpoint is selected in the Lenze setting via the analog input 1.
•Scaling: 10V 100 % reference speed (C011
)
The main setpoint is transformed to a speed setpoint in the setpoint encoder via a ramp func-
tion generator with linear or S-shaped ramps.
For a detailed functional description see FB L_NSet_1
. ( 230)
Related topics:
Analog terminals
( 112)
Parameterising analog input
( 113)
7.1.1.2 Motor potentiometer function
Alternatively, the main speed setpoint can be generated via a motor potentiometer function.
In the Lenze setting, the motor potentiometer function is deactivated.
Activation is possible via C806
or via the bMPotEnable input.
The behaviour of the motor potentiometer during switch-on of the drive system can be selected
in C805
.
For a detailed functional description see FB L_MPot_1
. ( 226)
7.1.1.3 Process controller
A process controller (PID controller) is connected downstream of the setpoint generator.
In the Lenze setting, the process controller is deactivated.
The activation is executed by selecting the operating mode in C242
.
For a detailed functional description see FB L_PCTRL_1
. ( 233)
nInflu_a
(C830/9)
Limitation of the influencing factor in percent
Speed setpoint
(C050)
Speed setpoint
Parameter Info